Results 1 - 20 de 71
Filter
1.
Rev. colomb. anestesiol ; 52(1)mar. 2024.
Article in English | LILACS-Express | LILACS | ID: biblio-1535711

ABSTRACT

During the past two decades, the videolaryngoscope (VDL) has become a valuable and effective tool for the management of the airway, not just in the realm of anesthesiology, but also in other medical specialties in clinical scenarios requiring tracheal intubation. In countries such as the United States, this represents over 15 million cases in the operating room and 650,000 outside the OR. The overall accumulated incidence of difficult airway is 6.8% events in routine practice and between 0.1 and 0.3 % of failed intubations, both associated with complications such as desaturation, airway injury, hemodynamic instability and death. Notwithstanding the fact that the VDL has proven advantages such as improved visualization of the glottis, higher first attempt success rates, and a shortened learning curve, most of the time its use is limited to rescue attempts or as a secondary option. The aim of this article is to comment the advantages and limitations of the VDL vs. the direct laryngoscope in a wide range of clinical settings, including the operating room, intensive care units, emergency departments, pediatrics, obstetrics, and Covid-19 to consider its routine use.


En las últimas dos décadas, el videolaringoscopio (VDL) se ha convertido en una herramienta valiosa y eficaz para el manejo de la vía aérea no solo en el ámbito de anestesiología, sino en otras especialidades médicas durante escenarios clínicos que requieren la intubación traqueal y las cuales, en países como Estados Unidos corresponden anualmente a más de 15 millones dentro de salas de cirugía y 650.000 fuera de ella. Aproximadamente, hay una incidencia global acumulada de 6,8 % de eventos de vía aérea difícil en la práctica rutinaria y 0,1 al 0,3 % de intubaciones fallidas, ambas asociadas a complicaciones como desaturación, daño en la vía aérea, inestabilidad hemodinámica y muerte. Pese a que el VDL ha demostrado ventajas como mejoría de la visualización de la glotis, aumento de tasa de éxito al primer intento y menor curva de aprendizaje, su uso en la mayoría de las veces se ve limitado como dispositivo de rescate o de manera secundaria. El propósito de este artículo es comentar acerca de las ventajas y limitaciones del VDL vs. el laringoscopio directo en un variado número de escenarios clínicos, como salas de cirugía, unidades de cuidado intensivo, emergenciología, pediatría, obstetricia y covid-19, con el fin de considerar si su uso debiera hacerse de manera rutinaria.

2.
Acta otorrinolaringol. cir. cuello (En línea) ; 51(2): 144-149, 20230000. ilus
Article in Spanish | LILACS, COLNAL | ID: biblio-1442514

ABSTRACT

Introducción: las infecciones profundas del cuello son patologías complejas con gran potencial de complicaciones graves, que, debido a su ubicación pueden ser de difícil reconocimiento y manejo. Es de gran importancia realizar un diagnóstico asertivo y ofrecer el tratamiento adecuado para poder disminuir las complicaciones que se pudieran presentar. La ecografía es una ayuda diagnóstica cada vez más utilizada que nos puede ayudar a guiar nuestras conductas de manera rápida y efectiva. Caso clínico: presentamos un caso de un paciente con un absceso en cuello, en el que la utilización de la ecografía de manera intraoperatoria facilitó la toma de decisiones y evitó procedimientos invasivos innecesarios. Conclusiones: el Point of Care Ultrasound (PoCUS) es una forma rápida y práctica de resolver preguntas y facilitar la toma de decisiones objetivas en el entorno perioperatorio.


Introduction: Deep neck infections are a complex group of pathologies with great potential for serious complications due to their location. Therefore, recognition and management can be a challenge. To reduce the risk of complications it is extremely important to have an assertive diagnosis y and offer the proper treatment. An ultrasound is a diagnosis tool that is being used more often because it can help us guide our medical decisions in a quick and effective way. Clinical case: We present a case of a patient who had an intraoperative ultrasound which helped in the decision making and avoided any further invasive procedures. Conclusions: The Point of Care Ultrasound (PoCUS) is a quick and practical way to solve questions and facilitate objective decisions in the perioperative environment.


Subject(s)
Humans , Male , Female , Airway Management , Neck , Case Reports , Ultrasonography , Abscess
3.
MedUNAB ; 25(3): [492-498], 01-12-2022.
Article in Spanish | LILACS | ID: biblio-1436139

ABSTRACT

Introducción. El manejo de la vía aérea difícil anticipada es un reto anestésico que supone la valoración preoperatoria de las características anatómicas y los factores de riesgo específicos del paciente. La intubación difícil se presenta en 1.6 de 1,000 eventos y la intubación fallida en 0.06 de 1,000 eventos. El objetivo de este reporte es mostrar la importancia del uso de dispositivos (específicamente videolaringoscopio) en pacientes con predicción de vía aérea difícil. Presentación del caso. Hombre de 63 años con gran masa facial con extensión a nariz, labio superior, erosión a nivel del maxilar superior que ocupaba cavidad oral, con predictores de ventilación e intubación difícil, programado para rinectomía, osteotomía Lefort II, reconstrucción y traqueostomía, con intubación exitosa con videolaringoscopio en primer intento bajo sedación consciente y ventilación espontánea. Discusión. La vía aérea difícil es un escenario relacionado a factores externos e internos del paciente y a complicaciones pre e intraoperatorias. El videolaringoscopio es una herramienta útil que permite la intubación exitosa y disminuye los posibles eventos adversos (como se observó en el paciente del caso presentado) y es descrito en diferentes reportes de casos con compromiso parcial o total de la vía aérea. Conclusión. La videolaringoscopia, en casos de vía aérea difícil anticipada, está asociada con un menor tiempo de intubación, un buen perfil de seguridad y una alta tasa de éxito, comparable a la del fibrobroncoscopio, se logra la intubación en el primer intento en la mayoría de las veces y, por ello, debería considerarse como primera opción.


Introduction. Management of an anticipated difficult airway is an anesthetic challenge that involves preoperative assessment of the patient's specific anatomic characteristics and risk factors. Difficult intubation occurs in 1.6 of 1,000 events and failed intubation in 0.06 of 1,000 events. The objective of this report is to show the importance of the use of devices (specifically videolaryngoscope) in patients with predicted difficult airway. Case Presentation. 63-year-old man with large facial mass with extensión to the nose, upper lip, erosion at the level of the upper jaw occupying the oral cavity, with predictors of ventilation and difficult intubation, scheduled for rhinectomy, Lefort II osteotomy, reconstruction and tracheostomy, with successful intubation with videolaryngoscope on the first attempt under conscious sedation and spontaneous ventilation. Discussion. Difficult airway is a scenario related to external and internal patient factors and to pre- and intraoperative complications. The videolaryngoscope is a useful tool that allows successful intubation and decreases possible adverse events (as observed in the patient of the case presented) and is described in different reports of cases with partial or total airway compromise. Conclusion. Videolaryngoscopy, in cases of anticipated difficult airway, is associated with a shorter intubation time, a good safety profile and a high success rate, comparable to that of fibrobronchoscopy, intubation is achieved on the first attempt in most cases and should therefore be considered as a first choice.


Introdução. O manejo da via aérea difícil antecipada é um desafio anestésico que envolve a avaliação pré-operatória das características anatômicas e dos fatores de risco específicos do paciente. A intubação difícil ocorre em 1.6 de 1,000 eventos e a intubação falha em 0.06 de 1,000 eventos. O objetivo deste relato é mostrar a importância do uso de dispositivos (especificamente videolaringoscópio) em pacientes com previsão de via aérea difícil. Apresentação do caso. Homem de 63 anos com grande massa facial estendendo-se ao nariz, lábio superior e erosão ao nível do maxilar superior que ocupava a cavidade oral, com preditores de ventilação e intubação difícil, programado para rinectomia, osteotomia Lefort II, reconstrução e traqueostomia, com intubação bem-sucedida, com videolaringoscópio na primeira tentativa sob sedação consciente e ventilação espontânea. Discussão. A via aérea difícil é um cenário relacionado a fatores externos e internos do paciente e a complicações pré e intraoperatórias. O videolaringoscópio é uma ferramenta útil que permite o sucesso da intubação e reduz possíveis eventos adversos (como observado no paciente do caso apresentado) e está descrito em diversos relatos de casos com comprometimento parcial ou total da via aérea. Conclusão. A videolaringoscopia, em casos de via aérea difícil antecipada, está associada a um menor tempo de intubação, um bom perfil de segurança e uma alta taxa de sucesso, comparável à fibrobroncoscopia, a intubação é realizada na primeira tentativa na maioria dos casos e, portanto, deve ser considerada como a primeira opção.


Subject(s)
Airway Management , Laryngoscopy , Carcinoma, Squamous Cell , Intubation , Anesthesia
4.
Rev. ADM ; 79(5): 271-275, sept.-oct. 2022. tab
Article in Spanish | LILACS | ID: biblio-1427848

ABSTRACT

Introducción: la vía aérea difícil es aquella situación clínica en la cual un anestesiólogo entrenado convencionalmente experimenta dificultad en la aplicación de ventilación con mascarilla facial, en la intubación endotraqueal o ambas, es de vital importancia su identificación, puesto que su manejo adecuado marcará la diferencia en el desenlace de los pacientes que requieren intubación, en especial los recibidos en urgencias. Objetivo: revisar de manera sistemática el estado actual del conocimiento y evidencia clínica relacionada al manejo de la vía aérea difícil en in- tubación de emergencia. Material y métodos: se realizó una revisión sistemática en PubMed, Cochrane, EBSCO y OVID; se emplearon los términos manejo de vía aérea difícil e intubación de emergencia. Resul- tados: la búsqueda arrojó 356 resultados, se excluyeron los estudios de revisión sistemática, metaanálisis, artículos basados en opiniones, infor- mes de casos, cartas al editor; 128 artículos fueron analizados; además, se buscó analizar artículos de distinta área de la investigación médica; se seleccionaron 21 artículos para ser analizados en esta revisión sistemática. Conclusiones: inesperadamente los artículos revisados concluyen, en su gran mayoría, que independientemente del protocolo de intubación, el aspecto que juega un rol determinante en el manejo de la vía aérea difícil es la experiencia y preparación previa del médico anestesiólogo (AU)


Introduction: difficult airway is that clinical situation in which a conventionally trained anesthesiologist experiences difficulty in ventilation with a face mask, in endotracheal intubation or both. In this review article we will focus on emergency intubation. Objective: to systematically review the current state of knowledge and clinical evidence related to the management of difficult airways in emergency intubation. Material and methods: a systematic review was carried out in PubMed, Cochrane data base, EBSCO and OVID; the terms: difficult airway management and emergency intubation; only clinical trials and scientific research reports were analyzed. Results: the search yielded 356 results, of which systematic review studies, meta-analysis, opinion-based articles, case reports, letters to the editor were excluded; which gave us 128 articles, after they were analyzed; it was also sought to analyze articles from different areas of medical research; 21 articles were selected to be analyzed in this systematic review. Conclusions: unexpectedly, the majority of the reviewed articles conclude that regardless of the intubation protocol or the tools used, the aspect that plays a decisive role in the management of the difficult airway is the experience and previous preparation of the anesthesiologist (AU))


Subject(s)
Humans , Emergencies , Airway Management , Intubation, Intratracheal/methods , Intubation, Intratracheal/adverse effects , Laryngoscopy/methods , Masks
5.
Fisioter. Pesqui. (Online) ; 29(4): 380-385, Oct.-Dec. 2022. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1421491

ABSTRACT

RESUMO A pressão do cuff (Pcuff) ideal deve ser capaz de prevenir a microaspiração de secreções orofaríngeas por escapes aéreos e evitar lesão da mucosa traqueal. Normalmente, realiza-se a monitorização por meio de manômetro, buscando manter a Pcuff entre 20 e 30cmH2O. O método do volume mínimo de oclusão (VMO) consiste em insuflar minimamente o balonete, utilizando uma seringa, para que não ocorram vazamentos. O objetivo deste estudo foi avaliar a capacidade do método do VMO de individualizar o ajuste da Pcuff em pacientes ventilados mecanicamente. Trata-se de um estudo transversal, prospectivo, com 25 pacientes adultos, com tempo de ventilação mecânica (VM) superior a 48 horas. A Pcuff foi medida em dois momentos: inicial e por VMO. A prevalência de Pcuff fora dos limites de normalidade foi de 76%. Ocorreu vazamento na medida inicial em nove pacientes, sendo que, para quatro, a medida estava dentro dos valores de referência. Os outros cinco apresentaram Pcuff<20cmH2O. No ajuste pelo método VMO, todos os pacientes apresentaram Pcuff no limite de normalidade. Os pacientes sem vazamento com Pcuff>30cmH2O tiveram redução quando ajustados pelo VMO (45,4±9,6 vs 28,5±1,6cmH2O; p<0,001). Podemos concluir que o método do VMO foi capaz de individualizar a Pcuff dentro dos valores de referência em todos os pacientes.


RESUMEN La presión del manguito (Pmanguito) ideal debería ser capaz de prevenir la microaspiración de secreciones orofaríngeas por el escape de aire y evitar daños en la mucosa traqueal. En general, la monitorización se da a través de un manómetro al buscar mantener la Pmanguito entre 20 y 30 cmH2O. La técnica de volumen de oclusión mínimo (VOM) consiste en inflar al mínimo el manguito, utilizando una jeringa, para que no escape el aire. El objetivo de este estudio fue evaluar la capacidad de la técnica de VOM para individualizar el ajuste de la Pmanguito en pacientes con ventilación mecánica. Se trata de un estudio transversal, prospectivo, realizado con 25 pacientes adultos, con tiempo de ventilación mecánica (VM) superior a 48 horas. La Pmanguito se dio en dos momentos: inicial y por VMO. La prevalencia de la Pmanguito fuera de los límites normales fue del 76%. Se detectó el escape de aire en la medida inicial de nueve pacientes, entre los cuales cuatro tuvieron una medición dentro de los valores de referencia. Los otros cinco tenían una Pmanguito<20cmH2O. En el ajuste por la técnica de VMO, todos los pacientes tuvieron Pmanguito al límite de los valores normales. Los pacientes que no habían presentado escape de aire con Pmanguito>30cmH2O tuvieron una reducción cuando hubo un ajuste del VMO (45,4±9,6 vs 28,5±1,6cmH2O; p<0,001). Se concluye que la técnica de VMO fue capaz de individualizar la Pmanguito dentro de los valores de referencia en todos los pacientes.


ABSTRACT The ideal cuff pressure (Pcuff) must prevent microaspiration of oropharyngeal secretions due to air leakage and avoid injury to the tracheal mucosa. Usually, monitoring consists of a manometer to keep the Pcuff between 20 and 30cmH2O. The minimal occlusive volume (MOV) method minimally inflates the cuff using a syringe so that no leakage occurs. This study aims to evaluate the ability of the minimal occlusive method to individualize the Pcuff adjustment in mechanically ventilated patients. Cross-sectional prospective study with 25 adult patients with more than 48 hours of mechanical ventilation. Cuff pressure was measured at two moments: initial and by MOV. The prevalence of Pcuff outside the normal range was 76%. Leakage in the initial measurement occurred in 9 patients, 4 of whom were within the reference values. The other 5 patients presented Pcuff<20cmH2O. In the adjustment by the MOV method, all patients presented Pcuff at the limit of normality. Patients without leakage with Pcuff>30cmH2O had a reduction when adjusted for MOV (45.4±9.6 against 28.5±1.6cmH2O; p<0.001). We can conclude that the minimal occlusive volume method was able to individualize the Pcuff within the reference values in all patients.

6.
Article in Spanish | LILACS, CUMED | ID: biblio-1408166

ABSTRACT

Introducción: El síndrome de Morquio es una enfermedad hereditaria autosómica recesiva con distintos grados de afectación al metabolismo de los glúcidos, lo que genera incapacidad para romper los enlaces de las cadenas largas de glucosamiglicanos, esto provoca acumulación de mucopolisacáridos en distintos tejidos del cuerpo humano. Objetivo: Describir el manejo anestésico de una gestante con síndrome de Morquio. Presentación del caso: Gestante primigesta de 30 años de edad, de raza negra, de 103 cm de estatura y 33 Kg de peso. Acude a consulta preoperatoria por presentar embarazo a término, baja talla y se realizó interrupción del embarazo por vía alta. Se procede a la valoración preanestésica donde se recoge antecedentes de enfermedad genética e ingreso previo por presentar cifras elevadas de tensión arterial. La paciente padecía de alergia a la dipirona. Conclusiones: Los pacientes con mucopolisacaridosis tienen una alta incidencia de dificultad para la ventilación y la intubación endotraqueal asociada con insuficiencia cardiopulmonar. La afectación de la columna presenta dificultades adicionales para los anestesiólogos. Cualquier cirugía electiva requiere una evaluación preoperatoria de los factores de riesgo anestesiológicos y la disponibilidad de un espectro de equipos para el manejo de las vías respiratorias. La anestesia debe ser realizada por un equipo con experiencia en el manejo de la vía aérea(AU)


Introduction: Morquio syndrome is an autosomal recessive hereditary disease that affects, to different extents, carbohydrate metabolism, which obstructs the ability to break bonds of long chains of glycosaminoglycans, causing mucopolysaccharides accumulation in different tissues of the human body. Objective: To describe the anesthetic management of a pregnant woman with Morquio syndrome. Case presentation: This is the case of a 30-year-old primigravid pregnant woman, of black skin, 103 cm of height and 33 kg of weight. She came for preoperative consultation because she was pregnant at term and had low body size; the pregnancy was terminated through the abdominal route. A preanesthetic assessment was performed, which permitted to observe a history of genetic disease and previous admission for high blood pressure. The patient was allergic to dipyrone. Conclusions: Among patients with mucopolysaccharidosis, there is a high incidence of difficulty for ventilation and endotracheal intubation associated with cardiopulmonary insufficiency. Spinal involvement represents additional difficulties for anesthesiologists. Any elective surgery requires preoperative assessment of anesthesiologic risk factors and the availability of a spectrum of airway management equipment. Anesthetic managment should be performed by a team experienced in airway management(AU)


Subject(s)
Humans , Female , Pregnancy , Adult , Mucopolysaccharidosis IV/surgery , Mucopolysaccharidosis IV/complications , Anesthesia, General/methods
7.
Acta otorrinolaringol. cir. cuello (En línea) ; 50(2): 144-149, 20220000. ilus, tab, graf
Article in Spanish | LILACS, COLNAL | ID: biblio-1382349

ABSTRACT

Introducción: el edema pulmonar posobstructivo (EPPO), o por presión negativa, es una entidad potencialmente mortal, que se desarrolla inmediatamente luego de una obstrucción severa de la vía aérea superior. Materiales y métodos: descripción de una serie de 4 casos de EPPO ocurridos en niños, 3 de ellos secundarios a aspiración de un cuerpo extraño y el otro como complicación de una adenoamigdalectomía. Discusión: la causa más frecuente de la obstrucción de la vía aérea es el laringoespasmo asociado con la manipulación de la vía aérea durante la intubación o las intervenciones quirúrgicas de la vía aérea. Tanto la adenoamigdalectomía, como la extracción de cuerpos extraños en la vía aérea constituyen unas de las intervenciones más frecuentes de la práctica otorrinolaringológica para el tratamiento de la obstrucción de la vía aérea; sin embargo, puede potencialmente desarrollar EPPO. Conclusión: Destacamos la importancia de que el otorrinolaringólogo tenga presente esta afección en niños que presentan dificultad respiratoria tras cualquier obstrucción o intervención quirúrgica de la vía aérea.si bien los cuerpos extraños en la vía aérea en niños suelen presentarse con crisis de asfixia, tos paroxística o dificultad respiratoria luego del evento, también debería pensarse la posibilidad de un evento de aspiración de un cuerpo extraño no presenciado ante un cuadro de edema pulmonar sin causa conocida. Si bien la adenoamigdalectomía es una de las cirugías más frecuente en la práctica otorrinolaringológica, esta potencialmente puede complicarse con EPPO.


Introduction: Post-obstructive pulmonary edema (POPE) or by Negative Pressure, is a potentially fatal entity that develops immediately after a severe obstruction of the upper airway. Materials and methods: Description of a series of four cases of POPE in children, three of them secondary to foreign body aspiration and the remaining one as a complication of adenotonsillectomy. Discussion: The most common etiology of airway obstruction is laryngospasm associated to airway manipulation during intubation or airway surgery. Both adenotonsillectomy and removal of foreign bodies in the airway are one of the most common procedures in otorhinolaryngology practice for management of airway obstruction, however, they can potentially develop EPPO. Conclusion: Although airway foreign bodies in children usually present with sudden episode of choking, paroxysmal cough and/or respiratory distress, the likelihood of an unwitnessed foreign body aspiration event in the presence of unexplained pulmonary edema should also be considered. Although adenotonsillectomy is one of the most common surgeries in ENT practice, it can potentially be complicated by EPPO. We emphasize the importance of the otorhinolaryngologist keeping this condition in mind in children who present respiratory distress after any obstruction or surgical intervention of the airway.


Subject(s)
Humans , Pulmonary Edema , Airway Management , Foreign Bodies
8.
Alerta (San Salvador) ; 4(3): 108-103, jul. 29, 2021. ilus
Article in Spanish | LILACS, BISSAL | ID: biblio-1282080

ABSTRACT

La intubación submentoniana es útil en procedimientos quirúrgicos en donde la intubación nasotraqueal está contraindicada y la intubación orotraqueal no es ideal debido a la fijación intermaxilar. Este informe describe dos pacientes masculinos que se presentaron al Hospital Nacional Rosales, en el servicio de Cirugía Maxilofacial de El Salvador, con historia de sufrir accidente de tránsito. El primer caso evidenció al examen radiológico fractura simple y desplazada de sínfisis mandibular, fractura simple huesos propios nasales y desviación del tabique nasal. El segundo caso es un paciente con fractura de sínfisis y doble cóndilo mandibular que presentaba imposibilidad a la apertura bucal. A través de la técnica del cirujano maxilofacial Hernández Altemir (España), el tubo endotraqueal atraviesa una incisión extraoral en la región submentoniana del suelo de la boca, para poder practicar reducción abierta de fracturas faciales, logrando adecuada oclusión, con mínimos cuidados posoperatorios y con una cicatriz estética. Al terminar la cirugía, la posición del tubo endotraqueal regresa a su posición original y el paciente evoluciona satisfactoriamente


Submental intubation is useful in surgical procedures where nasotracheal intubation is contraindicated and orotracheal intubation is not ideal due to intermaxillary fixation. This report describes two male patients who presented to the Rosales National Hospital, in the Maxillofacial Surgery service of El Salvador, with a history of suffering a traffic accident. The first case showed a simple and displaced fracture of the mandibular symphysis, simple nasal bone fracture and deviation of the nasal septum on radiological examination. The second case is a patient with a symphysis fracture and a double mandibular condyle that presented an inability to open the mouth. Through the technique of the maxillofacial surgeon Hernández Altemir (Spain), the endotracheal tube passes through an extraoral incision in the submental region of the floor of the mouth, in order to perform open reduction of facial fractures, achieving adequate occlusion, with minimal postoperative care and with an aesthetic scar. At the end of the surgery, the position of the endotracheal tube returns to its original position and the patient evolves satisfactorily


Subject(s)
Humans , Airway Management , Intubation , Maxillofacial Injuries
9.
Rev. colomb. anestesiol ; 49(2): e400, Apr.-June 2021. tab, graf
Article in English | LILACS, COLNAL | ID: biblio-1251500

ABSTRACT

Abstract Perioperative morbidity and mortality are high among patients in the extremes of life undergoing anesthesia. Complications in children occur mainly as a result of airway management-related events such as difficult approach, laryngospasm, bronchospasm and severe hypoxemia, which may result in cardiac arrest, neurological deficit or death. Reports and new considerations that have changed clinical practice in pediatric airway management have emerged in recent years. This narrative literature review seeks to summarize and detail the findings on the primary cause of morbidity and mortality in pediatric anesthesia and to highlight those things that anesthetists need to be aware of, according to the scientific reports that have been changing practice in pediatric anesthesia. This review focuses on the identification of "new" and specific practices that have emerged over the past 10 years and have helped reduce complications associated with pediatric airway management. At least 9 practices grouped into 4 groups are described: assessment, approach techniques, devices, and algorithms. The same devices used in adults are essentially all available for the management of the pediatric airway, and anesthesia-related morbidity and mortality can be reduced through improved quality of care in pediatrics.


Resumen Los pacientes en extremos de la vida sometidos a anestesia tienen la más alta morbimortalidad perioperatoria. Los niños se complican principalmente por eventos derivados del manejo de la vía aérea pediátrica (VAP), como dificultad en su abordaje, laringoespasmo, broncoespasmo e hipoxemia severa, que pueden terminar en paro cardiaco, déficit neurológico o muerte. En los últimos años se han informado y retomado aspectos que cambian la práctica clínica sobre la VAP Esta revisión narrativa de la literatura busca concretar y resumir estos hallazgos sobre la primera causa de morbimortalidad en anestesia pediátrica y enfatizar en lo que los anestesiólogos deben conocer, con base en los informes científicos que vienen cambiando la práctica anestésica pediátrica. Esta revisión busca identificar las conductas "nuevas" y concretas que han surgido en los últimos 10 años, y que ayudan a disminuir las complicaciones derivadas del manejo de la VAP Se señalan y describen al menos nueve conductas agrupadas en 4 bloques: Evaluación, técnicas de abordaje, dispositivos y algoritmos. Actualmente se cuenta con prácticamente todos los dispositivos de adultos para el manejo de la VAP y con consideraciones específicas se puede mejorar la calidad de la atención y reducir la morbimortalidad anestésica en pediatría.


Subject(s)
Humans , Child, Preschool , Child , Algorithms , Airway Management , Indicators of Morbidity and Mortality , Equipment and Supplies , Anesthesia
10.
Rev. chil. anest ; 50(3): 480-488, 2021. ilus, tab
Article in Spanish | LILACS | ID: biblio-1525591

ABSTRACT

GOALS: Determine the success rate of guided intubation with a flexible bronchofibroscope (BFC) through supraglottic devices: I-gel or Fastrach, establish the degree of fibroscopic visualization and determine the insertion time of the laryngeal mask airway (LMA) and endotracheal intubation. METHODS: Experimental, prospective, comparative and randomized study of 60 ASA I-II-III patients, older than 18 years, undergoing elective surgeries that required general anesthesia and endotracheal intubation. After anesthetic induction, the assigned LMA was placed and intubation with BFC was performed through it. Both the success of laryngeal mask insertion and intubation were recorded, as well as the time (in seconds) equired for these procedures. The vision of the laryngeal structures was classified according to the Brimacombe Scale. RESULTS: The groups analyzed presented similar general characteristics. Insertion time of he LMA was significantly lower with I-gel than Fastrach (median 12 s vs 16 s. Respectively, p = 0.001). Also, in the intubation time BFC guided through the laryngeal mask, differences in favor of I-gel were found, with a median of 72 s. vs 89 s. (p = 0.001). Regarding the degree of glottic visualization with BFC, no statistically significant differences were found between both groups.CONCLUSIONS: Although both devices had the highest success rate (both in their placement and in intubation through them), with I-gel the intubation was performed quicker.


OBJETIVOS: Determinar la tasa de éxito de intubación guiada con broncofibroscopio flexible (BFC) a través de los dispositivos supraglóticos: I-gel o Fastrach, establecer el grado de visualización fibroscópica y determinar el tiempo de inserción de la máscara laríngea y de intubación endotraqueal. MATERIALES Y MÉTODOS: Estudio experimental, prospectivo, comparativo y aleatorizado de 60 pacientes ASA I- II ­III, mayores de 18 años, sometidos a cirugías electivas que requerían anestesia general e intubación endotraqueal. Luego de la inducción anestésica, se procedió a colocar la máscara laríngea asignada y se realizó la intubación con BFC a través de la misma. Tanto el éxito de inserción de máscara laríngea como de intubación fueron registrados, así como el tiempo (en segundos) requerido para dichos procedimientos. La visión de las estructuras laríngeas fue clasificada de acuerdo a Escala de Brimacombe. RESULTADOS: Los grupos analizados presentaron características generales similares. El tiempo de inserción de la ML fue significativamente menor con I-gel que con Fastrach (medianas: 12 s. vs 16 s. respectivamente, p = 0,001). También en el tiempo de intubación guiada con BFC a través de la máscara laríngea, se encontraron diferencias en favor de I-gel, con una mediana de 72 s. vs 89 s. (p = 0,001). Respecto al grado de visualización glótica con BFC, no se encontraron diferencias estadísticamente significativas entre ambos grupos. CONCLUSIONES: Aunque ambos dispositivos tuvieron la máxima tasa de éxito (tanto en su colocación como en la intubación a través de ellos), con I-gel se realizó la intubación de manera más rápida.


Subject(s)
Humans , Adult , Middle Aged , Respiration, Artificial/methods , Bronchoscopy/methods , Laryngeal Masks , Time Factors , Body Weight , Prospective Studies , Treatment Outcome , Fiber Optic Technology , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods
11.
Rev. latinoam. enferm. (Online) ; 29: e3434, 2021. tab
Article in English | BDENF, LILACS | ID: biblio-1280484

ABSTRACT

Objective: construction and validation in appearance and content of the competence frameworks and of the Entrustable Professional Activities to develop skills in the training of nurses to assist the airway of adult patients in urgency and emergency situations. Method: a descriptive and methodological study developed in four phases: in the first, a workshop was held, composed of experts, for the construction of the competence frameworks; in the second, the material was validated using the Snowball Technique and the Delphi Technique, in the third, content analysis and calculation of the Content Validation Index were conducted; and in the fourth phase, the Entrustable Professional Activities were built, validated in simulated workshops. Results: the competence frameworks were built and validated, with a resulting CVI≥0.85 in all the items. The Entrustable Professional Activities were validated by experts regarding their applicability; of these, 44% stated they were applicable in simulated environments, 100% that they were useful content and with appropriate language, 22% suggested the insertion of new items to assess competence, 11% reported the difficulty of assessing competence individually in the clinical settings, and 11% of the experts referred to the need for prior training of the teacher/facilitator to use it. Conclusion: the study resulted in the construction of competence frameworks and six Entrustable Professional Activities relating them to the domains of essential competences in the training of nurses to assist the airway of adult patients in urgency and emergency situations. The participation of experts in the construction and validation of this material was essential to guarantee the theoretical and practical relevance of the result.


Objetivo: construção e validação em aparência e conteúdo dos marcos de competências e das Entrustable Professional Activities para desenvolver as competências na formação do enfermeiro para a assistência à via aérea de pacientes adultos em urgência e emergência. Método: estudo descritivo, metodológico desenvolvido em quatro fases: na primeira realizou-se uma oficina, composta por experts, para a construção dos marcos de competências; na segunda houve a validação dos material através da Snowball Technique e Técnica Delphi, na terceira ocorreu a análise de conteúdo e cálculo do Índice de Validação de Conteúdo; e na quarta fase foram construídas as Entrustable Professional Activities, validadas em oficinas simuladas. Resultados: construídos e validados os marcos de competências resultando em todos os itens IVC≥0,85. As Entrustable Professional Activities foram validadas por experts quanto à sua aplicabilidade, destes 44% referiram serem aplicáveis em ambientes simulados, 100% refeririam ser um conteúdo útil e com linguagem adequada, 22% sugeriram a inserção de novos itens para avaliar a competência, 11% relataram a dificuldade de avaliar a competência individualmente nos cenários clínicos, 11% experts referiram a necessidade de capacitação prévia do docente/facilitador para a utilização. Conclusão: o estudo resultou na construção dos marcos de competências e seis Entrustable Professional Activities relacionando-os com os domínios de competências essenciais na formação do enfermeiro para a assistência à via aérea de pacientes adultos em urgência e emergência. A participação dos experts na construção e na validação desse material foi fundamental para garantir a relevância teórica e prática do resultado.


Objetivo: construcción y validación de la apariencia y el contenido de los marcos de competencias y de las Entrustable Professional Activities para desarrollar las competencias en la formación de enfermeros para asistir la vía aérea de pacientes adultos en urgencia y emergencia. Método: estudio descriptivo, metodológico desarrollado en cuatro fases: en la primera se realizó un taller, integrado por experts, para la construcción de marcos de competencias; en el segundo se realizó la validación de los materiales a través de la Snowball Technique y la Técnica Delphi, en el tercero se realizó el análisis de contenido y cálculo del Índice de Validación de Contenido; y en la cuarta fase se construyeron Entrustable Professional Activities, validadas en talleres simulados. Resultados: se construyeron y validaron marcos de competencias, resultando en todos los ítems IVC≥0,85. Las Entrustable Professional Activities fueron validadas por experts en cuanto a su aplicabilidad, de estos el 44% dijo que eran aplicables en entornos simulados, el 100% dijo que eran contenidos útiles y con lenguaje adecuado, el 22% sugirió la inserción de nuevos ítems para evaluar competencia, el 11% reportó dificultad para evaluar la competencia individualmente en entornos clínicos, el 11% de los experts reportó la necesidad de capacitación previa del docente/facilitador para utilizarla. Conclusión: el estudio resultó en la construcción de marcos de competencias y seis Entrustable Professional Activities relacionándolos con los dominios de competencias esenciales en la formación de enfermeros para asistir la vía aérea de pacientes adultos en urgencia y emergencia. La participación de experts en la construcción y validación de este material fue fundamental para asegurar la relevancia teórica y práctica del resultado.


Subject(s)
Humans , Male , Female , Adult , Delphi Technique , Clinical Competence , Emergency Nursing , Education, Nursing , Airway Management , Nurses , Nursing Assessment
12.
Rev. ecuat. pediatr ; 21(3): 1-9, 31 Diciembre 2020.
Article in Spanish | LILACS | ID: biblio-1146530

ABSTRACT

Introducción: La máscara laríngea es el equipamiento con el objetivo de aumentar la calidad, seguridad, cuidado, sin embargo, a pesar de tener uso universal y alta eficacia para la ventilación no está exenta de complicaciones. El objetivo de la presente Investigación fue identificar la frecuencia de complicaciones con el uso de mascara laríngea en los hospitales públicos Vicente Corral Moscoso y José Carrasco en la ciudad de Cuenca. Métodos: Es un estudio observacional, descriptivo, prospectivo, en 220 pacientes pediátricos, ASA I , II y III intervenidos en cirugías electivas y emergentes bajo anestesia general en un intervalo de tiempo de 30 a 240 minutos, de todas las especialidades médicas quirúrgicas del año 2018 ,se utilizaron los diferentes tipos de máscara. La muestra se obtuvo aplicando la fórmula para población desconocida (n = (Z2 x p x q)/ e2), nivel de confianza (Z): 95%. (1.96) Margen de error (e): 5% Probabilidad de ocurrencia del evento (p): 15% Probabilidad de no ocurrencia del evento (q): 85%. Resultados: 220 casos ingresados al estudio. El índice de complicaciones laríngeas es 5.9% , frecuentemente la tos y secreción sanguinolenta, asociándose factores como mascara clásica, edad (2-5 años), tiempo mayor de 60 minutos, mayor número de intentos, ASA> I, estado nutricional sobrepeso, e insertar en formación. Conclusión: La máscara laríngea es validada como dispositivo en anestesia pediátrica por aprendizaje rápido, baja tasa de fracaso, menores complicaciones y utilidad en vías aéreas difíciles, Es insuficiente la evidencia para respaldar el uso de un determinado dispositivo por encima de otro


Introduction: The laryngeal mask is the equipment with the aim of increasing quality, safety, care, however, despite having universal use and high efficacy for ventilation, it is not without complications. The objective of this research was to identify the frequency of complications with the use of a laryngeal mask in the Vicente Corral Moscoso and José Carrasco public hospitals in the city of Cuenca. Methods: It is an observational, descriptive, prospective study in 220 pediatric patients, ASA I, II and III who underwent elective and emergent surgeries under general anesthesia in a time interval of 30 to 240 minutes, of all surgical medical specialties of the year 2018, the different types of mask were used. The sample was obtained by applying the formula for unknown population (n = (Z2 x p x q) / e2), confidence level (Z): 95%. (1.96) Margin of error (e): 5% Probability of occurrence of the event (p): 15% Probability of non-occurrence of the event (q): 85%. Results: 220 cases entered the study. The rate of laryngeal complications is 5.9%, frequently cough and bloody discharge, associating factors such as classic mask, age (2-5 years), time greater than 60 minutes, greater number of attempts, ASA> I, nutritional status, overweight, and insert in formation. Conclusion: The laryngeal mask is validated as a device in pediatric anesthesia due to rapid learning, low failure rate, fewer complications and usefulness in difficult airways. The evidence is insufficient to support the use of a certain device over another.


Subject(s)
Humans , Laryngeal Masks , Airway Management , Anesthesia, General , Child
13.
Notas enferm. (Córdoba) ; 20(36): 46-56, nov.2020.
Article in Spanish | UNISALUD, BINACIS, BDENF, LILACS | ID: biblio-1140729

ABSTRACT

Mundialmente el reconocimiento de la importancia de contar con una vía aérea permeable en una situación de emergencia o urgencia ha llegado a su punto máximo. Es por esto mismo que la búsqueda de alternativas a los métodos tradicionales para la obtención de esta misma, es un desafío para los profesionales de la salud. Se han descripto múltiples dispositivos para lograr este objetivo, dentro de los cuales se encuentra el tubo laríngeo, presentando diversas ventajas y mínimas desventajas, respaldado por distintos y variados estudios que han probado su eficiencia frente a otros dispositivos que tienen el mismo fin. El objetivo del presente trabajo es lograr la unificación del procedimiento en la colocación del tubo laríngeo por parte del personal Profesional de Enfermería[AU]


Globally, the recognition of the importance of having a permeable airway in an emergency or urgent situation has reached its peak. It is for this reason that the search for alternatives to traditional methods for obtaining it is a challenge for health professionals. Multiple devices have been described to achieve this objective, among which is the laryngeal tube, presenting various advantages and minimal disadvantages, supported by different and varied studies that have proven their efficiency against other devices that have the same purpose. The aim of the present work is to achieve the unification of the procedure in the placement of the laryngeal tube by the Professional Nursing staff[AU]


Globalmente, o reconhecimento da importância de ter uma via aérea permeável em uma situação de emergência ou urgência atingiu seu auge. É por isso que a busca por alternativas aos métodos tradicionais de obtenção é um desafio para os profissionais de saúde. Vários dispositivos têm sido descritos para atingir esse objetivo, entre os quais está o tubo laríngeo, apresentando diversas vantagens e desvantagens mínimas, amparados por diversos e variados estudos que comprovaram sua eficácia contra outros dispositivos com a mesma finalidade. O objetivo do presente trabalho é alcançar a unificação do procedimento na colocação da sonda laríngea pela equipe de profissionais de enfermagem[AU]


Subject(s)
Humans , Security Measures , Coronavirus Infections/prevention & control , Airway Management , Intubation , Larynx
14.
Rev. cir. (Impr.) ; 72(5): 449-454, oct. 2020. tab, ilus
Article in Spanish | LILACS | ID: biblio-1138737

ABSTRACT

Resumen El nuevo coronavirus (SARS-CoV-2), causante de la enfermedad COVID-19, es una pandemia con alta morbimortalidad mundial. Uno de los factores más importantes es su alta tasa de transmisibilidad por gotitas, aerosoles y fómites. La tendencia actual es el aumento progresivo de pacientes contagiados en nuestro país y, por consiguiente, de mayor cantidad de enfermos en unidades de cuidados intensivos (UCI) con uso de ventilación mecánica invasiva (VMI). La traqueostomía (TQT) se utiliza en pacientes críticos para facilitar la VMI a largo plazo y el destete de la ventilación. Una TQT temprana, definida como la realizada en los primeros 7 días después de la intubación orotraqueal (IOT), se asocia a una reducción en el tiempo de la VMI, mortalidad y permanencia en UCI. La TQT es una técnica quirúrgica con alta generación de aerosoles la cual implica medidas especiales frente a la realización de ésta en pacientes con COVID-19. Para limitar el contagio del SARS-CoV-2 en los trabajadores de salud es necesario el uso de elementos de protección personal (EPP) adecuados según la intervención a realizar. Es por esta razón que en el presente artículo se propone utilizar el acrónimo C-O-RO-NA para no olvidar elementos y pasos fundamentales al momento de realizar esta técnica, minimizando de esta manera el contagio en los trabajadores de salud.


The new coronavirus (SARS-CoV-2), which causes COVID-19 disease, is a high mortality pandemic illness. One of the most important factors is its high rate of transmissibility by respiratory droplets, aerosols and fomites. The reigning trend of this disease is progressively increasing infected patients in our country, therefore, more patients in intensive care units (ICU) with invasive mechanical ventilation (IMV). Tracheostomy (TQT) is used in critical patients to facilitate long-term IMV and ventilation weaning. An early TQT, defined as performed in the first 7 days after orotracheal intubation (IOT) is associated with a reduction IMV duration, mortality rate and length of stay in ICU. TQT is a surgical procedure which generates a huge amount of aerosols that need special measures to perform in COVID-19 patients. It is necessary to use appropriate personal protection elements (PPE) according to the intervention, limiting the spread of SARS-CoV-2 in health workers. It is for this reason that this article proposes to use the acronym C-O-RO-NA to remember fundamental elements and steps when performing this technique in order to minimize health workers infection.


Subject(s)
Humans , Pneumonia, Viral/prevention & control , Tracheostomy/methods , Coronavirus Infections/prevention & control , Surgical Procedures, Operative/standards , Clinical Protocols , Pandemics , Personal Protective Equipment/standards , Betacoronavirus
15.
Salud UNINORTE ; 36(1): 256-280, ene.-abr. 2020. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1252131

ABSTRACT

RESUMEN Objetivo: En la presente revisión narrativa se realiza una descripción de las técnicas de manejo de la vía aérea en paciente con diagnóstico de COVID-19. Materiales y métodos: Se realizó una exhaustiva búsqueda bibliográfica en las bases de datos Science Direct y PubMed. Se incluyeron artículos originales y artículos de revisión. También se incluyeron actualizaciones de las entidades internacionales y nacionales acerca de la situación actual de la infección por SARS-CoV-2 y el manejo de la vía aérea en pacientes con diagnóstico de COVID-19. Resultados: Para el manejo de la vía aérea en pacientes con diagnóstico de COVID-19 es imprescindible el uso del equipo de protección completa. El profesional de la salud debe estar capacitado para la realización de los procedimientos necesarios para llevar a cabo dicho tópico. Se debe tener presente que aplicarlos de forma ordenada, rápida y eficaz reducirá la exposición al SARS-CoV-2. Conclusiones: Se considera que al realizar todos los pasos adecuados para el manejo de la vía aérea en este tipo de pacientes se reducirá notablemente la posibilidad de contagio de un profesional de la salud. Sin embargo, cabe resaltar que actualmente muchas instituciones no cuentan con todo el equipo de protección o con el personal capacitado para llevar a cabo tan importante tarea; por lo cual se están investigado medidas más económicas tanto para el manejo de la vía aérea como para la rehabilitación de estos pacientes.


ABSTRACT Objective: In this narrative review, a description is made of airway management techniques in a patient diagnosed with COVID-19. Materials and Methods: A comprehensive bibliographic search of the Science Direct and PubMed databases was performed using the keywords. Original articles and review articles were included. Updates from international and national entities on the status of SARS-CoV-2 infection and airway management in patients diagnosed with COVID-19 were also included. Results: For the management of the airway in patients diagnosed with COVID-19, the use of complete protective equipment is essential. The health professional must be trained to carry out the necessary procedures for this topic. Keep in mind that applying them in an orderly, fast and effective way will reduce exposure to SARS-CoV-2. Conclusions: It is considered that, by performing all the appropriate steps for airway management in this type of patient, the possibility of contagion from a health professional will be greatly reduced. However, it should be noted that currently many institutions do not have all the protective equipment or trained personnel to carry out such an important task, for which cheaper measures are being investigated for both airway management and rehabilitation of these patients.

16.
Rev. latinoam. enferm. (Online) ; 28: e3347, 2020. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1126960

ABSTRACT

Objective: to compare the mean development time of the techniques of direct laryngoscopy and insertion of supraglottic devices; and to evaluate the success rate in the first attempt of these techniques, considering health professionals wearing specific personal protective equipment (waterproof overalls; gloves; boots; eye protection; mask). Method: meta-analysis with studies from LILACS, MEDLINE, CINAHL, Cochrane, Scopus and Web of Science. The keywords were the following: personal protective equipment; airway management; intubation; laryngeal masks. Results: in the "reduction of the time of the procedures" outcome, the general analysis of the supraglottic devices in comparison with the orotracheal tube initially presented high heterogeneity of the data (I2= 97%). Subgroup analysis had an impact on reducing heterogeneity among the data. The "laryngeal mask as a guide for orotracheal intubation" subgroup showed moderate heterogeneity (I2= 74%). The "2ndgeneration supraglottic devices" subgroup showed homogeneity (I2= 0%). All the meta-analyses favored supraglottic devices. In the "success in the first attempt" outcome, moderate homogeneity was found (I2= 52%), showing a higher proportion of correct answers for supraglottic devices. Conclusion: in the context of chemical, biological or radiological disaster, the insertion of the supraglottic device proved to be faster and more likely to be successful by health professionals. PROSPERO record (CRD42019136139).


Objetivo: comparar o tempo médio do desenvolvimento das técnicas de laringoscopia direta e de inserção de dispositivos supraglóticos e avaliar a taxa de sucesso na primeira tentativa dessas técnicas, considerando a utilização de equipamentos de proteção individual específicos (macacão impermeável; luvas; botas; proteção ocular; máscara) pelos profissionais de saúde. Método: metanálise com estudos das bases LILACS, MEDLINE, CINAHL, Cochrane, Scopus e Web of Science. As palavras-chave foram: personal protective equipment; airway management; intubation; laryngeal masks. Resultados: no desfecho redução "do tempo dos procedimentos" a análise geral dos dispositivos supraglóticos em comparação com o tubo orotraqueal apresentou inicialmente alta heterogeneidade dos dados (I2 = 97%). A análise por subgrupos impactou na redução da heterogeneidade entre os dados. O subgrupo "máscara laríngea como guia para intubação orotraqueal" demonstrou heterogeneidade moderada (I2 = 74%). O subgrupo "dispositivos supraglóticos de 2ª geração" evidenciou homogeneidade (I2 = 0%). Todas as metanálises foram favoráveis aos dispositivos supraglóticos. No desfecho "êxito na primeira tentativa" foi encontrada homogeneidade moderada (I2 = 52%), demonstrando maior proporção de acerto para dispositivos supraglóticos. Conclusão: no contexto do desastre químico, biológico ou radiológico, a inserção do dispositivo supraglótico revelou ser mais rápida e apresentar maior chance de acerto por profissionais de saúde. Registro PROSPERO (CRD42019136139).


Objetivo: comparar el tiempo medio de desarrollo de las técnicas de laringoscopia directa y de inserción de dispositivos supraglóticos y evaluar la tasa de éxito obtenida en el primer intento de dichas técnicas con profesionales sanitarios provistos de equipos de protección individual específicos (mono impermeable, guantes, botas, protección ocular, mascarilla). Método: meta-análisis con estudio de las bases de datos LILACS, MEDLINE, CINAHL, Cochrane, Scopus y Web of Science. Las palabras clave fueron las siguientes: personal protective equipment; airway management; intubation; laryngeal masks. Resultados: en el resultado "reducción del tiempo de los procedimientos", el análisis general de los dispositivos supraglóticos en comparación con el tubo orotraqueal presentó, inicialmente, una alta heterogeneidad de los datos (I2= 97%). El análisis por subgrupos dio como resultado una reducción de la heterogeneidad entre los datos. El subgrupo "mascarilla laríngea como guía para la intubación orotraqueal" mostró una heterogeneidad moderada (I2= 74%). El subgrupo "dispositivos supraglóticos de 2ª generación" mostró homogeneidad (I2= 0%). Todos los meta-análisis fueron favorables a los dispositivos supraglóticos. En el resultado "éxito en el primer intento" se halló una homogeneidad moderada (I2= 52%), obteniendo una mayor proporción de aciertos con el uso de dispositivos supraglóticos. Conclusión: en el contexto de un desastre químico, biológico o radiológico, se ha demostrado que la inserción del dispositivo supraglótico es más rápida y que los profesionales sanitarios obtienen una mayor probabilidad de acierto. Registro PROSPERO (CRD42019136139).


Subject(s)
Protective Devices , Bathroom Equipment , Incidence , Laryngeal Masks , Meta-Analysis , Disasters , Airway Management , Personal Protective Equipment , Equipment and Supplies Utilization , Intubation , Laryngoscopy
17.
Fisioter. Pesqui. (Online) ; 26(4): 427-432, out.-dez. 2019. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1056204

ABSTRACT

ABSTRACT Several respiratory diseases are characterized by hypersecretion, requiring airway clearance therapy (ACT). Oral high-frequency oscillation (OHFO) devices are effective to enable daily ACT; however, they are still too expensive to become available for low-income patients. We sought to develop a low-cost device (OHFO-LC) and compare its physical properties with those OHFO commercially available (Shaker and Flutter). The OHFO-LC was developed from polyvinyl chloride material and one stainless steel sphere. Pressures and frequencies were measured at flows of 4, 6, 8, 10 and 15L/min. Pressures at the mouthpieces were measured by a transducer connected to a microcomputer. The oscillation frequencies were obtained from the graph of the pressure. The frequencies and pressures were compared among groups using one-way Anova and Tukey's post hoc tests, p≤0.05. There were no differences among the frequencies of the three devices in all tested flows. The OHFO-LC device showed a higher positive expiratory pressure compared with the Shaker at all tested flows (4 L/min: 4.7±1.2 vs. 1.0±0.2 cmH2O; 6 L/min: 8.6±1.5 vs. 3.5±0.5 cmH2O; 8 L/min: 10.8±1.6 vs. 5.4±0.2 cmH2O; 10 L/min: 13.5±1.2 vs. 7.7±0.4 cmH2O; 15 L/min: 14.3±1.1 vs. 7.8±0.2 cmH2O; OHFO-LC vs. Shaker; p≤0.05) and at 10 and 15 L/min compared with Flutter (10 L/min: 13.5±1.2 vs. 7.5±1.2 cmH2O; 15 L/min: 14.3±1.1 vs. 8.2±1.2 cmH2O; OHFO-LC vs. Flutter, p≤0.05). The cost of the OHFO-LC device was much lower than both the Shaker and the Flutter. Our results showed that the OHFO-LC had physical properties with similar frequencies but higher pressures than other OHFO devices that are commercially available. Future studies are necessary to evaluate its clinical efficacy.


RESUMO Diversas doenças respiratórias são caracterizadas por hipersecreção com necessidade de higiene brônquica (HB). Osciladores orais de alta frequência (OOAF) são dispositivos que promovem HB diária; entretanto, seu custo pode ser inviável para aquisição por pacientes com baixa renda. Os objetivos deste estudo foram: desenvolver um OOAF de baixo custo (OOAF-BC) e comparar suas propriedades físicas com as dos disponíveis comercialmente (Shaker e Flutter). O OOAF-BC foi desenvolvido com material de polivinil clorido e uma esfera de aço inoxidável. As pressões e frequências foram mensuradas nos fluxos de 4, 6, 8, 10 e 15 L/min. As pressões nos bocais foram medidas por um transdutor conectado ao computador. As frequências de oscilação foram derivadas do gráfico de pressão. A comparação dos dispositivos foi feita por Anova com post hoc de Tukey, p≤0.05. Não houve diferença entre as frequências dos três dispositivos em todos os fluxos testados. O OOAF-BC apresentou pressão mais alta comparado ao Shaker em todos os fluxos testados (4 L/min: 4,7±1,2 vs. 1,0±0,2 cmH2O; 6 L/min: 8,6±1,5 vs. 3,5±0,5 cmH2O; 8 L/min: 10,8±1,6 vs. 5,4±0.2 cmH2O; 10 L/min: 13,5±1,2 vs. 7,7±0.4 cmH2O; 15 L/min: 14,3±1,1 vs. 7,8±0,2 cmH2O; OOAF-BC vs. Shaker; p≤0.05) e nos fluxos de 10 e 15 L/min comparado ao Flutter (10 L/min: 13,5±1,2 vs. 7,5±1,2 cmH2O; 15 L/min: 14,3±1,1 vs. 8,2±1,2 cmH2O; OOAF-BC vs. Flutter, p≤0.05). O custo do OOAF-BC foi pelo menos seis vezes menor. O OOAF-BC apresentou frequências similares e pressões mais altas que os outros OOAF comercialmente disponíveis. Estudos futuros são necessários para avaliar sua eficácia clínica.


RESUMEN Varias enfermedades respiratorias se caracterizan por hipersecreción, que requiere higiene bronquial (HB). Los osciladores orales de alta frecuencia (OOAF) son dispositivos que promueven la HB diaria; sin embargo, su costo puede no ser factible para la adquisición por parte de pacientes con bajos ingresos. Los objetivos de este estudio fueron desarrollar un OOAF de bajo costo (OOAF-BC) y comparar sus propiedades físicas con las de los disponibles comercialmente (Shaker y Flutter). El OOAF-BC se desarrolló con material de polivinilo clorado y una bola de acero inoxidable. Las presiones y frecuencias se midieron en flujos de 4, 6, 8, 10 y 15 L/min. Las presiones de la boquilla se midieron mediante un transductor conectado a la computadora. Las frecuencias de oscilación se derivaron del gráfico de presión. Se compararon los dispositivos con la utilización de Anova con post hoc de Tukey, p≤0,05. No hubo diferencias entre las frecuencias de los tres dispositivos en todos los flujos probados. El OOAF-BC mostró una presión más alta en comparación con Shaker en todos los flujos probados (4 L/min: 4,7±1,2 vs. 1,0±0,2 cmH2O; 6 L/min: 8,6±1,5 vs. 3,5±0,5 cmH2O; 8 L/min: 10,8±1,6 vs. 5,4±0,2 cmH2O; 10 L/min: 13,5±1,2 vs. 7,7±0,4 cmH2O; 15 L/min: 14,3±1,1 vs. 7,8±0,2 cmH2O; OOAF-BC vs. Shaker; p≤0,05) y con flujos de 10 y 15 L/min en comparación con Flutter (10 L/min: 13,5±1,2 vs. 7,5±1,2 cmH2O; 15 L/min: 14,3±1,1 vs. 8,2±1,2 cmH2O; OOAF-BC vs. Flutter, p≤0,05). El costo de OOAF-BC fue al menos seis veces menor. El OOAF-BC mostró frecuencias similares y presiones más altas que otros OOAF disponibles comercialmente. Se necesitan estudios futuros para evaluar su eficacia clínica.

18.
Rev. colomb. anestesiol ; 47(4): 245-248, Oct-Dec. 2019. graf
Article in English | LILACS, COLNAL | ID: biblio-1042735

ABSTRACT

Abstract We report an unexpected difficult airway in a patient with unrecognized lingual tonsillar hypertrophy. A 54-year-old hypertensive woman presented for resection of a mediastinal mass under general anesthesia (GA). After induction, mask ventilation was impossible. Laryngeal mask airway (LMA) was used, achieving suboptimal ventilation. Fiberoptic intubation through LMA was attempted but tube advancement was hindered by a protrudingmass. Finally, intubation was achieved using the Frova introducer. After completion of the surgery, the patient was transferred, intubated, to the postanesthesia care unit. Ear, nose, and throat assessment concluded that the mass was a hyper-trophied lingual tonsil. Unexpected lingual tonsillar hypertrophy can complicate GA, making mask ventilation, and even intubation impossible. It is considered a frequent cause of unexpected difficult airway. Diagnosis cannot be made by standard airway physical examination. Once recognized, fiberoptic intubation is mandatory in subsequent surgeries.


Resumen Presentamos el caso de una vía aérea difícil imprevista debido a hipertrofia de la amígdala lingual no conocida. Mujer de 54 años, hipertensa, que ingresa para resección de masa mediastínica bajo anestesia general. Tras la inducción, la ventilación mediante mascarilla facial resultó imposible. Se coloca mascarilla laríngea (ML) y se consigue ventilación de forma subóptima. Se intenta intubación guiada por fibroscopia a su través, pero se objetiva masa protruyente que impide la progresión del tubo. Finalmente se intuba mediante introductor Frova. Tras finalizar la cirugía, la paciente se traslada intubada a la Unidad de Reanimación Postanestésica (URPA). Se realiza evaluación por otorrinolaringología (ORL), que concluye que la masa corresponde a una amígdala lingual hipertrófica. La hipertrofia de la amígdala lingual puede complicar la anestesia, dificultando la ventilación e intubación. Se considera una causa frecuente de vía aérea difícil imprevista. El diagnóstico no puede realizarse mediante exploración anestésica estándar. Una vez conocida, las intubaciones siguientes deben ser guiadas por fibroscopia.


Subject(s)
Humans , Female , Middle Aged , Pharynx , Amygdalin , Hypertrophy , Otolaryngology , Tongue , Palatine Tonsil , Ventilation , Laryngeal Masks
20.
Rev. chil. anest ; 48(2): 123-128, 2019. tab
Article in Spanish | LILACS | ID: biblio-1451690

ABSTRACT

INTRODUCTION: Treacher Collins syndrome is a rare disorder of the craniofacial development that constitutes a challenge for anesthesiologists, since it represents a difficult airway in the majority of cases. The main objective of this article is to provide a bibliographic review about how the airway management of patients with Treacher Collins syndrome has been managed. MATERIALS AND METHODS: A literature review was carried out in the following databases: PubMed, EMBASE and ScienceDirect. DISCUSSION: The factors that increase the risk of difficult airway in these patients are presented as well as the strategies to handle it. CONCLUSION: The Treacher Collins syndrome presents a high risk of difficult airway, therefore careful planning of airway management is mandatory and there are different strategies to handle it.


INTRODUCCIÓN: El síndrome de Treacher Collins (STC) es un trastorno inusual del desarrollo craneofacial que constituye un reto para el anestesiólogo, ya que éste condiciona la condición de vía aérea difícil en la mayoría de los casos. El objetivo principal de este artículo es realizar una revisión bibliográfica de cómo se han manejado casos de vía aérea difícil ligados al síndrome de Treacher Collins. MATERIALES Y MÉTODOS: Se realizó una revisión de la literatura disponible en las siguientes bases de datos: PubMed, EMBASE y ScienceDirect. DISCUSIÓN: Se presentan los factores que aumentan el riesgo de vía aérea difícil en estos pacientes, así como las estrategias para manejarla. CONCLUSIÓN: El síndrome de Treacher Collins presenta un alto riesgo de vía aérea difícil, por lo tanto, es obligatoria la planificación cuidadosa de la misma, contando con diferentes estrategias para manejarla.


Subject(s)
Humans , Airway Management/methods , Anesthesia , Mandibulofacial Dysostosis/complications , Bronchoscopy/methods , Laryngeal Masks
SELECTION OF CITATIONS
SEARCH DETAIL